Showing posts with label Battery. Show all posts
Showing posts with label Battery. Show all posts

Gel Batteries Advantages

Batteries

Gel Stationary Batteries

Gel battery is a type of lead-acid battery with a sulfuric acid gelled electrolyte.
Sulfuric acid is mixed with a silica forms in a mass consistence of gel.
The gel batteries used grids made ​​of lead alloys without antimony.
Each gel-cell battery has a one-way self-sealing valve which opens in case of increased pressure inside the battery and release gases outside protecting the housing from bursting.
Gel batteries uses a recombination process which eliminates the need for adding water.

Gel Battery Advantages

  • does not require a special room with ventilation
  • work buffer are characterized by long life
  • for cyclic operation are characterized by high number of cycles (loading - unloading)
  • does not require constant maintenance or refilling of electrolyte
  • conduct heat very well generated by battery at a flow of current
  • increased the maximum battery power due to low internal resistance.
  • low self-discharge ensures trouble-free storage battery

Leia Mais >>

The advantages of AGM batteries

In AGM - (Absorbed Glass Mat) batteries the electrolyte is trapped in the separators of glass fiber with a high porosity. AGM batteries are sealed batteries and thus can operate in any position.
Under normal operating conditions AGM do not emit gases, due to non- leakage construction in use are safe and harmless to the environment (there is no danger of scalding with sulfuric acid). Due to the fact that they do not emit gases do not require a special room with ventilation. They have self-sealing one-way valve, which opens in case of increase of pressure inside the battery and releases the gases outside of the container to protect against explosion. Maintenance-free batteries use recombination process or chemical reactions by which oxygen and hydrogen generated by overcharging the battery in a classic, they are expelled into the atmosphere, the battery remains in the form of water and eliminate the need for its replenishment.

The advantages of AGM batteries:

- Lower purchasing costs compared to counterparts in gel technology
- High current yield with discharges of large currents in a short time,
- Smaller capacity batteries can be used for discharges higher currents

Leia Mais >>

The Advantages of vrla batteries

A valve regulated lead-acid (VRLA) battery is a starved electrolyte AGM (absorbent glass mat) type battery and has a safety valve which prevents excessive build up of gas pressure inside the battery. Valve-regulated lead acid batteries rely upon internal gas recombination to minimize electrolyte loss over the life of the battery, thereby eliminating the need for re-watering. A lead-acid battery has lead positive plates, lead oxide negative plates, and an electrolyte which is a solution of sulfuric acid and distilled water. The plates and the plate separator material between them are arranged in plate packs in plate compartments. A valve regulated lead acid battery comprises separators and plates stacked within a sealed container, in which an electrolyte in a cell is retained in the pores of the separators and both of positive and negative electrode plates so as not to flow. VRLA recombination batteries offer a number of advantages compared to flooded cell batteries. The starved acid design of the battery facilitates the oxygen recombination reaction. The recombination reactions are facilitated by the starved acid or electrolyte condition where the electrolyte is immobilized in glass separators disposed between the plates of the battery. VRLA batteries are particularly suited for remote back-up power applications because they do not require the same type of periodic maintenance required by flooded cells. These differing maintenance requirements provide cost savings when VRLA batteries are used.

Valve-regulated lead-acid (VRLA) batteries are used in telecommunications networks for standby power systems. An advantage of VRLA batteries is that they are maintenance-free. On the other hand, these batteries are completely sealed, which makes it extremely difficult to determine deterioration levels. A useful battery test system for estimating the battery deterioration was developed in NTT and NTT Power and Building Facilities Inc. It can measure the battery's capacity in less than 1 ms without affecting telecommunications equipment or power equipment, and it is accurate to within 10%, and is compact, light, and easy to handle. However, as this method measures minute levels of resistance, precise measurements are difficult under high noise environment such as UPS systems. This paper describes the types of noises applied to VRLA batteries in telecommunications power supply systems. It also introduces a method whereby measurements are conducted while high noise exists

Advantages vrla batteries
Do not require a special room with ventilation
Are environmentally friendly
The working buffer are characterized by long life (several years)
The cyclic operation is characterized by a high number of cycles (loading - unloading)
Does not require constant maintenance or refilling of electrolyte
Have a lower internal resistance and higher power efficiency than conventional batteries
Are much smaller and almost half of the lighter than conventional batteries, with equal volumes
The cyclic operation is characterized by a high number of cycles (loading - unloading)
Are safe and easy to use, in constant readiness to work.

Leia Mais >>

  ©Energihub.blogspot.com - Todos os direitos reservados.